Research Products

LIFECODES Fluoroanalyzer

LIFECODES Fluoroanalyzer

  • Amplified DNA can be analyzed with up to 100 different SSO probes simultaneously
  • Detection of antibodies in serum directed against up to 100 different antigens in a single well with sensitivity similar to flow cytometry
  • Multiplex reactions reduce labor, consumables and assay time
  • XY platform allows walk-away acquisition from 1 to 96 samples at a time
  • Convenience of automated analysis
  • Powered by xMAP technology from Luminex
As of March 22, 2013, LIFECODES is now part of Immucor. For more information, click here.
DescriptionQuantityCatalog
LIFECODES Fluoroanalyzer
Includes: LX200 analyzer, XY Luminex platform, PC with Luminex IS 2.3 software, Quick-Type for LifeMatch analysis software
  888310
LIFECODES Fluoroanalyzer Calibration Beads
Cal 1 Calibration Beads -- Classification Laser Calibrator
5mL 628006
LIFECODES Fluoroanalyzer Calibration Beads
Cal 2 Calibration Beads -- Reporter Laser Calibrator
5mL 628007
LIFECODES Fluoroanalyzer Control Beads
Con 1 Control Beads -- Classification Signal Control
5mL 628008
LIFECODES Fluoroanalyzer Control Beads
Con 2 Control Beads -- Reporter Signal Control
5mL 628009
LIFECODES Fluoroanalyzer Sheath Delivery System
Sheath Delivery System
  888305
LIFECODES Fluoroanalyzer Sheath Fluid
Sheath Fluid
20L 628005
LIFECODES Fluoroanalyzer Concentrated Sheath Fluid
20x Concentrated Sheath Fluid
1L 628025
As of March 22, 2013, LIFECODES is now part of Immucor. For more information, click here.

The Luminex 200 System has been 510(k) cleared by the FDA. Kits developed by Luminex strategic partners that have received 510(k) clearance from the FDA can be used on the Luminex 200 system for diagnostic purposes.

 

LUMINEX is a trademark of Luminex Corporation

As of March 22, 2013, LIFECODES is now part of Immucor. For more information, click here.
 
As of March 22, 2013, LIFECODES is now part of Immucor. For more information, click here.

Accuracy and Precision:

  • Sample uptake volume ±5%
  • Classification of microspheres >80%
  • Misclassification of microsphere <2%
  • May vary by xMAP microsphere product lines. Refer to the specific product information sheet for further details
  • Temperature control 0°C to +2°C of target
  • Internal sample carryover <0.9%
  • Soluble background fluorescence emissions at 575 nm automatically subtracted from fluorescence intensity values

Sensitivity

  • Detects 1000 fluorochromes phycoerythrin (PE) per xMAP microsphere
  • Reporter channel dynamic range: 3.5 decades of detection

Optics

  • Reporter laser: 532 nm, nominal output 10-15 mW, maximum 500mW, frequency doubled diode; mode of operation, continuous wave (CW)
  • Classification laser: 635 nm, 9.1 ±6%, maximum output 25 mW, diode; mode of operation, continuous wave (CW)
  • Reporter detector: Photomultiplier tube, detection bandwidth of 565-585 nm
  • Classification detector and doublet discriminator: Avalanche photo diodes with temperature compensation
  • Fluidics
  • Sheath flow rate: 90 µL ± 5 µL/second
  • Cuvette: 200 micron square flow channel
  • Sample injection rate: 1µL/second
  • Sample update volume: 20-200 µL

Capacity

  • The specifications below reflect minimum capacity values:
  • Analyze multiple 96-well plates per batch
  • Analyze multiple assay templates per plate
  • Automatic sampling from a 96-well plate. The following microtiter plates are compatible with the Luminex XY Platform plate holder: flatbottom, conical, round, filter bottom, half plates [overall height no more than 0.75" (19mm)], any color
  • Sheath container and waste container hold enough volume to run up to two 96-well plates between refills
  • Distinguish a minimum of 1 to a maximum of 100 unique xMAP microsphere sets in a single sample
  • Detect and distinguish surface reporter fluorescence emissions at 575 nm on the surface of 1-100 unique xMAP microsphere sets in a single sample

General

  • Operating temperature: 15°C to 30°C (59°F to 86°F)
  • Humidity: 20% to 80%, non-condensing
  • Altitude: Operation up to 2400 m (7874 ft) above mean sea level
  • Physical dimensions: 43 cm (17") W x 50.5 cm (20") D x 24.5 cm (9.5") H
  • Weight: 25 kg (60 lbs.)
  • UL Installation Category II, as defined in Annex J of the UL 61010A-1
  • UL Pollution Degree 2, as defined in Section 3.7.3.2 of UL 61010A-1
  • Luminex® 200 analyzer, input voltage range: 100-120V~±10%, 1.4 Amp, and 200-240 V~±10%, 0.8 Amp, 47-63 Hz

PC Specifications

  • Intel Pentium IV or equivalent class PC, minimum speed 933 MHz
  • Main memory: minimum of 512 MB
  • Hard disk drive: 10 GB minimum storage capacity
  • Communication/Ports: minimum of one parallel port, 2 RS-232 compatible serial ports, and one USB version 1.1 compatible high speed port
  • Read, write and removable media: CDR/W drive
  • Operating system: Microsoft Windows XP Pro SP2
  • CE marked and UL listed
  • Two-button mouse or equivalent

 

LUMINEX is a trademark of Luminex Corporation. INTEL and PENTIUM are trademarks of Intel Corporation. MICROSOFT and WINDOWS XP are trademarks of Microsoft Corporation.