Gen-Probe Fluoroanalyzer
Gen-Probe Fluoroanalyzer

- Amplified DNA can be analyzed with up to 100 different SSO probes simultaneously
- Detection of antibodies in serum directed against up to 100 different antigens in a single well with sensitivity similar to flow cytometry
- Multiplex reactions reduce labor, consumables and assay time
- XY platform allows walk-away acquisition from 1 to 96 samples at a time
- Convenience of automated analysis
- Powered by xMAP technology from Luminex
| Description | Quantity | Catalogue |
|---|---|---|
| Gen-Probe Fluoroanalyzer Includes: LX200 analyzer, XY Luminex platform, PC with Luminex IS 2.3 software, Quick-Type for LifeMatch analysis software |
888310 | |
| Gen-Probe Fluoroanalyzer Calibration Beads Cal 1 Calibration Beads -- Classification Laser Calibrator |
5mL | 628006 |
| Gen-Probe Fluoroanalyzer Calibration Beads Cal 2 Calibration Beads -- Reporter Laser Calibrator |
5mL | 628007 |
| Gen-Probe Fluoroanalyzer Control Beads Con 1 Control Beads -- Classification Signal Control |
5mL | 628008 |
| Gen-Probe Fluoroanalyzer Control Beads Con 2 Control Beads -- Reporter Signal Control |
5mL | 628009 |
| Gen-Probe Fluoroanalyzer Sheath Delivery System Sheath Delivery System |
888305 | |
| Gen-Probe Fluoroanalyzer Sheath Fluid Sheath Fluid |
20L | 628005 |
| Gen-Probe Fluoroanalyzer Concentrated Sheath Fluid 20x Concentrated Sheath Fluid |
1L | 628025 |
Accuracy and Precision:
- Sample uptake volume ±5%
- Classification of microspheres >80%
- Misclassification of microsphere <2%
- May vary by xMAP microsphere product lines. Refer to the specific product information sheet for further details
- Temperature control 0°C to +2°C of target
- Internal sample carryover <0.9%
- Soluble background fluorescence emissions at 575 nm automatically subtracted from fluorescence intensity values
Sensitivity
- Detects 1000 fluorochromes phycoerythrin (PE) per xMAP microsphere
- Reporter channel dynamic range: 3.5 decades of detection
Optics
- Reporter laser: 532 nm, nominal output 10-15 mW, maximum 500mW, frequency doubled diode; mode of operation, continuous wave (CW)
- Classification laser: 635 nm, 9.1 ±6%, maximum output 25 mW, diode; mode of operation, continuous wave (CW)
- Reporter detector: Photomultiplier tube, detection bandwidth of 565-585 nm
- Classification detector and doublet discriminator: Avalanche photo diodes with temperature compensation
- Fluidics
- Sheath flow rate: 90 µL ± 5 µL/second
- Cuvette: 200 micron square flow channel
- Sample injection rate: 1µL/second
- Sample update volume: 20-200 µL
Capacity
- The specifications below reflect minimum capacity values:
- Analyze multiple 96-well plates per batch
- Analyze multiple assay templates per plate
- Automatic sampling from a 96-well plate. The following microtiter plates are compatible with the Luminex XY Platform plate holder: flatbottom, conical, round, filter bottom, half plates [overall height no more than 0.75" (19mm)], any color
- Sheath container and waste container hold enough volume to run up to two 96-well plates between refills
- Distinguish a minimum of 1 to a maximum of 100 unique xMAP microsphere sets in a single sample
- Detect and distinguish surface reporter fluorescence emissions at 575 nm on the surface of 1-100 unique xMAP microsphere sets in a single sample
General
- Operating temperature: 15°C to 30°C (59°F to 86°F)
- Humidity: 20% to 80%, non-condensing
- Altitude: Operation up to 2400 m (7874 ft) above mean sea level
- Physical dimensions: 43 cm (17") W x 50.5 cm (20") D x 24.5 cm (9.5") H
- Weight: 25 kg (60 lbs.)
- UL Installation Category II, as defined in Annex J of the UL 61010A-1
- UL Pollution Degree 2, as defined in Section 3.7.3.2 of UL 61010A-1
- Luminex® 200 analyzer, input voltage range: 100-120V~±10%, 1.4 Amp, and 200-240 V~±10%, 0.8 Amp, 47-63 Hz
PC Specifications
- Intel Pentium IV or equivalent class PC, minimum speed 933 MHz
- Main memory: minimum of 512 MB
- Hard disk drive: 10 GB minimum storage capacity
- Communication/Ports: minimum of one parallel port, 2 RS-232 compatible serial ports, and one USB version 1.1 compatible high speed port
- Read, write and removable media: CDR/W drive
- Operating system: Microsoft Windows XP Pro SP2
- CE marked and UL listed
- Two-button mouse or equivalent
LUMINEX is a trademark of Luminex Corporation. INTEL and PENTIUM are trademarks of Intel Corporation. MICROSOFT and WINDOWS XP are trademarks of Microsoft Corporation.